Sign In | Join Free | My futurenowinc.com
China Anhui Feichun Special Cable Co., Ltd logo
Anhui Feichun Special Cable Co., Ltd
"Feichun Cable: Special wear-resistant flexible cable designed for Reeling & Trailing scenarios!"
Active Member

2 Years

Home > Shipboard & Marine Cables >

Feichun FMSGSGO VG95218T63 Marine Power Cables - Comprehensive Analysis and Application Guide

Anhui Feichun Special Cable Co., Ltd
Contact Now

Feichun FMSGSGO VG95218T63 Marine Power Cables - Comprehensive Analysis and Application Guide

Brand Name : FeiChun™

Model Number : FMSGSGO VG95218T63

Certification : VDE 0250 Part 813

Place of Origin : Hefei Anhui China

MOQ : 200 Meter

Price : 10-50 USD per meter, price varies according to specifications

Payment Terms : T/T, Western Union

Supply Ability : 18,000 meters per week

Delivery Time : 15-30 Work Day

Packaging Details : Cable Reels or Packaging Bags

Conductor Integrity : Reliable Conductor Integrity

Bend Radius : 10 inches

Outstanding Flexibility : Extremely Flexible

Maximum Ampacity : 170 Amps

Insulation Material : XLPE

Uv Stability : UV Stable Structure

Number Of Conductors : 3

Current Rating : 1000A

Stranding : 7 strands

Easy Installation Process : Easy To Install

Oil Resistant : Yes

Outstanding Durability : Durable And Reliable

Voltage : 0.6/1kV

Operating Temperature : -40°C to +90°C

Contact Now

Feichun FMSGSGO VG95218T63 Marine Power Cables - Comprehensive Analysis and Application Guide

1. Introduction

Overview of Feichun FMSGSGO VG95218T63 Halogen-Free Light Power Cables

When it comes to marine electrical systems, safety, durability, and reliability are paramount. Feichun FMSGSGO VG95218T63 halogen-free light power cables are designed to meet the rigorous demands of shipboard installations.

These cables are manufactured to the highest standards, ensuring reliable operation in harsh marine environments.

Feichun FMSGSGO VG95218T63 Marine Power Cables - Comprehensive Analysis and Application Guide

Significance in Marine Applications

Marine vessels operate in environments characterized by saltwater exposure, extreme temperatures, and constant vibration.

Feichun FMSGSGO VG95218T63 cables offer halogen-free construction, fire resistance, and superior durability, making them indispensable for ensuring safe and efficient operations on ships.

Compliance with VG 95218 Part 63 Standards

The Feichun FMSGSGO VG95218T63 is compliant with the VG 95218 Part 63 standard, ensuring it meets stringent military and maritime requirements. It also adheres to Bureau Veritas (BV) 3400 guidelines for installation, guaranteeing a high level of safety and performance.

Scope of Application

These cables are ideal for fixed installations on ships, suitable for all locations, including open decks exposed to environmental stressors.


Feichun FMSGSGO VG95218T63 Marine Power Cables - Comprehensive Analysis and Application Guide

2. Technical Specifications and Standards Compliance

2.1 Core Construction

Copper Conductor Specifications

The core conductor is made of plain, round stranded copper, compliant with VG 95218 Part 63.

Stranding Benefits:

Flexibility: Stranded conductors allow easy routing, even in tight spaces.

Corrosion Resistance: The high-quality copper withstands salt spray and moisture exposure.

Insulation Material

The cores are insulated with cross-linked LS0H (Low Smoke Zero Halogen) material.

Advantages:

Fire Safety: Emits minimal smoke during a fire, aiding in evacuation.

Environmental Compliance: Free from toxic halogens, reducing the risk of corrosion to nearby equipment.

Screen Construction and Braiding

Screen Type: Braided screen of bare copper.

Purpose:

Protects against electromagnetic interference (EMI).

Ensures signal integrity and reduces the risk of cross-talk.

Outer Sheath

The outer sheath is made of crosslinked polymer, offering exceptional protection.

  • Durability: Resistant to abrasion, chemicals, and UV radiation.

  • Flexibility: Maintains performance under extreme conditions.


2.2 Electrical Characteristics

Parameter Value
Nominal Voltage (U) 250 V
Test Voltage 2 kV
Max Conductor Temp 90°C
Short Circuit Temp 250°C

These characteristics ensure reliable power delivery in dynamic marine environments.


2.3 Thermal Properties

Thermal Property Value
Ambient Temperature (Fixed) -30°C to 90°C
Laying Temperature (Min) -15°C
Short Circuit Temperature Limit 250°C

The wide temperature range ensures performance stability in both polar and tropical climates.


Feichun FMSGSGO VG95218T63 Marine Power Cables - Comprehensive Analysis and Application Guide

3. Safety and Environmental Compliance

3.1 Fire Performance

  • Flame Retardancy: Complies with EN/IEC 60332-1-2 and EN/IEC 60332-1-24, minimizing fire spread risks.

  • Low Smoke: Tested under IEC/EN 61034-2, ensuring low smoke density for improved visibility during fire emergencies.

  • Halogen-Free: Certified to IEC/EN 60754-1/2, reducing toxic gas emissions.

3.2 Chemical Resistance

  • Oil Resistance: Certified to IEC/EN 60811-404, ensuring durability against lubricants and fuels.

  • Ozone Resistance: Built to withstand prolonged exposure to ozone in marine atmospheres.


4. Installation Guidelines

4.1 Mechanical Properties

Parameter Value
Permanent Tensile Strength 50 N/mm²
Bending Radius 5 x OD (Outer Diameter)

Proper handling ensures longevity and performance.

4.2 Installation Best Practices

Cable Routing Considerations

  • Avoid sharp bends and maintain the minimum bending radius.

  • Use supports and ties to prevent sagging or movement.

Termination Techniques

  • Use appropriate glands to maintain IP rating and prevent moisture ingress.

  • Ensure proper earthing of the screen for EMI protection.

Feichun FMSGSGO VG95218T63 Marine Power Cables - Comprehensive Analysis and Application Guide

Support Spacing

Install supports at intervals to minimize mechanical stress and movement.


5. Common Installation Challenges and Solutions

5.1 Environmental Challenges

Challenge Solution
Salt Spray Exposure Use corrosion-resistant materials and seals.
Temperature Fluctuations Select cables rated for a wide temperature range.
Vibration Secure cables using vibration-dampening clamps.


6. Maintenance and Inspection

6.1 Routine Maintenance

  • Visual Inspections: Check for signs of wear, such as abrasions or cracks.

  • Insulation Resistance Testing: Verify electrical integrity.

6.2 Troubleshooting Guide

Common Faults:

Loose Connections: Tighten securely.

Abrasion: Replace damaged sections.


7. Regulatory Compliance and Documentation

7.1 Classification Society Requirements

  • Ensure compliance with BV 3400 installation regulations.

  • Maintain proper documentation, including test certificates.

7.2 Quality Assurance

  • All cables undergo stringent testing for compliance with VG 95218-63 and EN/IEC standards.


8. Conclusion

Feichun FMSGSGO VG95218T63 marine cables provide a robust, compliant, and environmentally friendly solution for shipboard installations.

With advanced materials and manufacturing processes, these cables ensure durability, safety, and performance reliability in the most challenging marine environments.

For further inquiries, contact Feichun Cable for expert advice and technical support.

Feichun FMSGSGO VG95218T63 Marine Power Cables - Comprehensive Analysis and Application Guide Feichun FMSGSGO VG95218T63 Marine Power Cables - Comprehensive Analysis and Application Guide Feichun FMSGSGO VG95218T63 Marine Power Cables - Comprehensive Analysis and Application Guide

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.


Wholesale Feichun FMSGSGO VG95218T63 Marine Power Cables - Comprehensive Analysis and Application Guide from china suppliers

Feichun FMSGSGO VG95218T63 Marine Power Cables - Comprehensive Analysis and Application Guide Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Anhui Feichun Special Cable Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)