Comprehensive Guide to Feichun TECWIND H07BN4-F Wind Turbine Cables: Technical Specifications, Applications, and Best Practices

Brand Name : FeiChun™

Model Number : TECWIND H07BN4-F Wind Turbine Cables

Certification : VDE 0250 Part 813

Place of Origin : Hefei Anhui China

MOQ : 200 Meter

Price : 10-30 USD per meter, price varies according to specifications

Payment Terms : T/T, Western Union

Supply Ability : 12,000 meters per week

Delivery Time : 15-30 Work Day

Packaging Details : Cable Reels or Packaging Bags

Flexible Handling : Easy Handling In Dynamic Conditions

Heat Tolerance : Withstands High Temperatures

Flexibility : Ultra-flexible Design

Sheath Color : Black

Waterproof : Suitable For Wet Conditions

Standard : IEC 60245, VDE 0282, BS EN 50525-2-21

Tailored For Handling : Enhances Material Handling Efficiency

Easy Installation : Flexible Installation

Chemical Resistance : Resistant To Chemicals

Wind Turbine Connectivity : Ideal For Wind Turbines

Operating Temperature : -40°C to +90°C

Nominal Outer Diameter : 6.8mm to 42.0mm

Voltage Rating : 450/750 V

Outer Diameter : 8.5mm to 35mm

Contact Now

Comprehensive Guide to Feichun TECWIND H07BN4-F Wind Turbine Cables: Technical Specifications, Applications, and Best Practices

Wind energy is one of the most sustainable power sources of our time. At the heart of wind turbines lies the critical component that ensures uninterrupted energy flow: high-performance cables.

Among these, the Feichun TECWIND H07BN4-F 450/750V Wind Turbine Cables stand out due to their robust design, adherence to international standards, and versatility in challenging environments.

Comprehensive Guide to Feichun TECWIND H07BN4-F Wind Turbine Cables: Technical Specifications, Applications, and Best Practices

These cables are engineered for medium mechanical strain in both flexible and fixed installations, offering exceptional performance under demanding conditions. Their 450/750V voltage rating ensures reliability, making them an excellent choice for renewable energy systems.


Technical Specifications

Cable Construction

The Feichun TECWIND H07BN4-F cables combine advanced materials and meticulous engineering to ensure durability and efficiency.

Feature Details
Conductor Bare, plain copper, fine wire, Class 5 (IEC 60228)
Core Insulation EPR rubber, providing excellent thermal and electrical properties
Outer Sheath EPR rubber with high resistance to UV, ozone, oil, and chemicals
Available Configurations Single-core and multi-core options, tailored to specific wind turbine applications

Performance Parameters

These cables excel in harsh conditions due to their superior performance specifications.

Parameter Value
Operating Temperature -40°C to 90°C
Short-Circuit Temperature Up to 250°C
Voltage Rating 450/750V
Torsional Stress ±150°/m
Bending Radius 6 × D (fixed), 10 × D (flexible)


Installation Guidelines

Mechanical Considerations

To ensure optimal performance, follow these mechanical guidelines during installation:

Parameter Specification
Bending Radius 6 × D for fixed installation, 10 × D for flexible use
Tensile Strength Varies by cross-section (e.g., 375N for 1x25 mm², 6000N for 1x400 mm²)
Torsional Stress ±150°/m to manage wind turbine movement

Environmental Factors

The cables' design ensures resistance to environmental challenges.

Resistance Standard
Chemical Resistance IEC/EN 60811-404
UV and Ozone High resistance, validated via XENO Test
Oil Resistance Verified according to DIN EN 60811-404


Sizing and Selection

Cross-Section Selection Criteria

Selecting the right cable cross-section is crucial for efficiency and safety.

Factor Guideline
Current-Carrying Capacity Refer to DIN VDE 0298-4, considering installation method and temperature correction factors.
Voltage Drop Ensure compliance with IEC 60364-5-52 standards to avoid excessive energy loss.
Short-Circuit Current Select a conductor size that withstands the required short-circuit current for the system.


Common Installation Challenges and Solutions

Mechanical Stress Management

Proper cable handling and installation techniques mitigate mechanical stress.

Challenge Solution
Excessive bending stress Adhere to bending radius guidelines.
Torsional loads from turbine rotation Use cables designed for ±150°/m torsional stress.
Vibration in wind turbines Secure cables with appropriate supports.

Environmental Protection

Environmental challenges can impact cable performance.

Challenge Solution
Moisture Exposure Use moisture-resistant sealing techniques and cable glands.
UV Radiation Deploy cables with tested UV-resistant outer sheaths.
Chemical Exposure Ensure the cable complies with IEC/EN 60811-404 for oil resistance.


Quality Assurance and Testing

Standard Compliance

The Feichun TECWIND H07BN4-F cables undergo rigorous testing to meet international standards.

Test Standard
Flame Propagation DIN EN 60332-1-2
Oil Resistance DIN EN 60811-404
UV Resistance XENO Test and ISO 4982-2

Performance Verification

Parameter Testing Method
Insulation Resistance Verified with voltage withstand and resistance tests
Conductor Integrity Measured via dimensional and resistance testing

Maintenance and Inspection

Routine Inspection Procedures

Regular inspections ensure the longevity and safety of the cables.

Aspect Inspection Focus
Visual Check for sheath damage and wear.
Electrical Test insulation resistance and voltage.
Mechanical Verify tension and bending compliance.


Appendices

Appendix A: Reference Standards

Standard Details
IEC 60228 Defines conductor classes and construction.
DIN EN 60811-404 Specifies oil resistance requirements.

Appendix B: Installation Checklists

Checklist Stage Key Tasks
Pre-Installation Verify cable length and cross-section.
During Installation Adhere to bending and tensile guidelines.
Post-Installation Perform testing and record all results.


The Feichun TECWIND H07BN4-F Wind Turbine Cables deliver exceptional performance, reliability, and compliance with international standards.

With robust design features and advanced materials, these cables are tailored for the demands of modern wind energy systems, ensuring efficiency and durability for years to come.

Comprehensive Guide to Feichun TECWIND H07BN4-F Wind Turbine Cables: Technical Specifications, Applications, and Best Practices Comprehensive Guide to Feichun TECWIND H07BN4-F Wind Turbine Cables: Technical Specifications, Applications, and Best Practices Comprehensive Guide to Feichun TECWIND H07BN4-F Wind Turbine Cables: Technical Specifications, Applications, and Best Practices

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.


Wholesale Comprehensive Guide to Feichun TECWIND H07BN4-F Wind Turbine Cables: Technical Specifications, Applications, and Best Practices from china suppliers

Comprehensive Guide to Feichun TECWIND H07BN4-F Wind Turbine Cables: Technical Specifications, Applications, and Best Practices Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Anhui Feichun Special Cable Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)