Sign In | Join Free | My futurenowinc.com
China Anhui Feichun Special Cable Co., Ltd logo
Anhui Feichun Special Cable Co., Ltd
"Feichun Cable: Special wear-resistant flexible cable designed for Reeling & Trailing scenarios!"
Active Member

2 Years

Home > LSZH Cable >

Feichun AJ-2YOF(L)2YDB2Y H95 Railway Signalling Cable: Reliable Performance for Advanced Railway Applications

Anhui Feichun Special Cable Co., Ltd
Contact Now

Feichun AJ-2YOF(L)2YDB2Y H95 Railway Signalling Cable: Reliable Performance for Advanced Railway Applications

Brand Name : FeiChun™

Model Number : AJ-2YOF(L)2YDB2Y H95

Certification : VDE 0250 Part 814

Place of Origin : Hefei Anhui China

MOQ : 200 Meter

Price : 10-30 USD per meter, price varies according to specifications

Payment Terms : T/T, Western Union

Supply Ability : 18,000 meters per week

Delivery Time : 15-30 Work Day

Packaging Details : Cable Reels or Packaging Bags

Underground Power : Reliable Power Transmission

Flame Resistance : Superior Fire Safety

Voltage Rating : 300/500V

Certifications : CE, RoHS, UL

Cable Length : 1000m

Conductor Material : Copper

Cable Type : Low Smoke Zero Halogen

Urban Expansion : Facilitates City Growth

Halogen Content : Zero

Impact Resistant : Resistant To Damage From Impacts

Flexibility : Easy Adaptation To Tunnel Contours

Insulation Material : LSZH

Outer Jacket : PVC / PUR

Shielding : Yes

Contact Now

Feichun AJ-2YOF(L)2YDB2Y H95 Railway Signalling Cable: Reliable Performance for Advanced Railway Applications

The Feichun AJ-2YOF(L)2YDB2Y H95 Railway Signalling Cable stands as a testament to innovation and reliability in railway signaling systems.

Designed for use in light signal operations, point machines, and similar applications, this cable delivers outstanding performance even in challenging environments.

Feichun AJ-2YOF(L)2YDB2Y H95 Railway Signalling Cable: Reliable Performance for Advanced Railway Applications

With enhanced mutual capacitance for long-distance transmission, robust mechanical protection, and superior induction shielding, this cable is the perfect choice for railway infrastructure along electrified tracks.


Key Features and Benefits

Optimized for Long-Distance Signaling

Improved mutual capacitance ensures clear signal transmission over extended distances, reducing the need for signal repeaters.

Enhanced Induction Protection


A copper wire screen shields against inductive interference caused by electrified tracks and nearby high-voltage systems.

Robust Mechanical Durability


Steel tape armouring safeguards the cable from physical damage, particularly in direct burial applications.

Water-Resistant Design


Equipped with longitudinal water blocking, the cable is suitable for direct burial and submersion, offering longevity in diverse environmental conditions.

Compliance with Deutsche Bahn Standards


Meeting PH 416.0114 v.2.1 specifications ensures seamless integration into Deutsche Bahn systems, guaranteeing quality and safety.


Technical Specifications

1. Conductor Characteristics

Feature Details
Material Copper
Stranding Pattern n x 1 x 1.4 mm or 1.8 mm
Conductor Resistance ≤ 11.9 Ω/km (1.4 mm), ≤ 7.2 Ω/km (1.8 mm)


2. Insulation and Construction

Component Material/Details
Core Insulation Polyethylene (PE)
Longitudinal Water Blocking Yes
Laminated Sheath Copolymer-coated aluminum tape (0.15 mm)
Inner Sheath Polyethylene (PE)
Screen Construction Copper wire screen for inductive shielding
Armouring Galvanized steel tape


3. Outer Sheath and Protection

Feature Details
Material Polyethylene (PE)
Environmental Suitability Direct burial and submersion


4. Electrical Characteristics

Property Value
Nominal Voltage (U/U0) 600V/420V
Test Voltage 2.5 kV (Core/Core and Core/Screen)
Insulation Resistance ≥ 1500 MΩ·km
Capacitance ≤ 95 nF/km (≤ 105 nF/km for single core)


5. Environmental Conditions

Condition Specification
Operating Temperature -40°C to +60°C
Laying Temperature -10°C to +60°C
Bending Radius ≥ 7.5–10 x outer cable diameter


Feichun AJ-2YOF(L)2YDB2Y H95 Railway Signalling Cable: Reliable Performance for Advanced Railway Applications

Standards and Compliance

The Feichun AJ-2YOF(L)2YDB2Y H95 cable is meticulously crafted to comply with Deutsche Bahn AG PH 416.0114 v.2.1, ensuring top-tier reliability and safety for critical railway signaling applications. Adherence to these rigorous standards guarantees seamless operation in even the most demanding scenarios.


Solving Common Challenges in Railway Signaling

1. Signal Attenuation Over Long Distances

Problem: Signal degradation reduces efficiency and reliability over extended distances.


Solution: The cable's improved mutual capacitance enables consistent and clear signal transmission, ensuring high performance in long-distance applications.


2. Inductive Interference

Problem: Electrified tracks often generate electromagnetic interference that disrupts signaling.


Solution: The copper wire screen offers effective shielding, minimizing interference and ensuring uninterrupted operations.


3. Mechanical Damage

Problem: Direct burial exposes cables to harsh environmental conditions, including rocks and shifting soil.


Solution: Steel tape armouring provides exceptional mechanical protection, ensuring durability and longevity.


4. Water Ingress

Problem: Water can compromise cable performance and longevity.


Solution: The longitudinal water blocking design prevents water penetration, making the cable reliable even in submerged conditions.


Feichun AJ-2YOF(L)2YDB2Y H95 Railway Signalling Cable: Reliable Performance for Advanced Railway Applications

Installation and Maintenance Best Practices

1. Direct Burial Installation

Step Best Practice
Trenching Use a trench depth of at least 600 mm to avoid damage.
Bedding Material Lay the cable on a sand bed or fine soil for stability.
Backfilling Carefully backfill with soft material to prevent damage.


2. Submersion Installation

Step Best Practice
Waterproofing Ensure all terminations are sealed against water ingress.
Laying Technique Use specialized tools to minimize stress on the cable.


3. Maintenance and Inspection

Action Frequency
Electrical Testing Annually, to ensure insulation and capacitance values.
Route Inspection Every 6 months, to check for physical damage or hazards.


Why Choose Feichun AJ-2YOF(L)2YDB2Y H95?

Reliability in Harsh Conditions


From humid submersion to dry burial, this cable performs consistently across environments.

Industry-Leading Compliance


Designed to meet Deutsche Bahn standards, ensuring seamless integration and reliability.

Cost Efficiency


Long-lasting construction and fewer maintenance needs lower operational costs over time.

The Feichun AJ-2YOF(L)2YDB2Y H95 Railway Signalling Cable is the ultimate solution for reliable, long-distance signal transmission in demanding railway environments.

With features like enhanced mutual capacitance, inductive interference protection, and robust armouring, it offers unparalleled performance for direct burial and submersion applications.

By following the provided installation and maintenance guidelines, you can ensure optimal functionality and longevity for your railway signaling systems.

Choose Feichun for cables that meet the highest standards and deliver unmatched performance.


Wholesale Feichun AJ-2YOF(L)2YDB2Y H95 Railway Signalling Cable: Reliable Performance for Advanced Railway Applications from china suppliers

Feichun AJ-2YOF(L)2YDB2Y H95 Railway Signalling Cable: Reliable Performance for Advanced Railway Applications Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Anhui Feichun Special Cable Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)