Brand Name : FeiChun™

Model Number : MVCECH 3.6/6 (7.2) kV

Certification : VDE 0250 Part 813

Place of Origin : Hefei Anhui China

MOQ : 200 Meter

Price : 10-30 USD per meter, price varies according to specifications

Payment Terms : T/T, Western Union

Supply Ability : 18,000 meters per week

Delivery Time : 15-30 Work Day

Packaging Details : Cable Reels or Packaging Bags

Oil Resistant : Yes

Uv Stability : UV Stable Structure

Stranding : 7 strands

Versatile Compatibility : Fits Various Equipment Configurations

Highly Reliable : Trustworthy In Critical Tasks

Bend Radius : 10 inches

Features : Flexible, Oil and Sunlight Resistant

Outstanding Flexibility : Extremely Flexible

Low Smoke Emission : Emits Minimal Smoke

Outstanding Durability : Durable And Reliable

Connector Type : NEMA L5-30P

Model : Corrosion-Proof Marine Cable

Sturdy Connector Design : Solid Connector Construction

Water Resistant : Yes

Contact Now

Powering Marine Vessels: A Guide to Feichun Type MVCECH 3.6/6 (7.2) kV Cable Marine Cables


I. Introduction: Meeting Medium Voltage Power Needs in Marine Applications

In the challenging world of marine environments, reliable medium voltage (MV) power distribution is crucial for ensuring the seamless operation of vessels.

Feichun, a leader in high-performance marine cabling, introduces the Type MVCECH 3.6/6 (7.2) kV Medium Voltage Cable, a solution tailored to meet the unique needs of marine systems.

Powering Marine Vessels: A Guide to Feichun Type MVCECH 3.6/6 (7.2) kV Cable Marine Cables

This article dives deep into the features, benefits, and best practices for installing and maintaining Feichun Type MVCECH cables.

Designed for fixed installations, this cable is engineered to handle electric power transport between the engine room generator and various electrical machines, delivering efficiency and minimizing electromagnetic interference (EMI) with its overall screen.

Key Features of Feichun Type MVCECH 3.6/6 (7.2) kV Cable

  • Voltage Rating: 3.6/6 (7.2) kV for medium voltage power distribution.

  • Application: Fixed installations in electromechanical and electronic equipment.

  • Temperature Resistance: Operates reliably from -40°C to +90°C with a minimum installation temperature of -15°C.

  • EMI Shielding: Features an overall screen to minimize electromagnetic interference.

  • Robust Construction: Withstands the harsh marine environment, including salt spray, humidity, and UV radiation.

For detailed specifications, such as core identification and current ratings, see the Technical Information Section at the end of this guide.


II. The Challenges of Medium Voltage Cabling and Feichun’s Solution

Addressing the Demands of Marine Power Distribution

Marine environments present a unique set of challenges that demand specialized solutions.

Feichun Type MVCECH cables are engineered to tackle these problems head-on:

Challenge Solution Provided by Feichun Type MVCECH Cable
High Voltage Stress Insulated with HF HEPR Compound, offering resistance to electrical stress and discharges.
Electromagnetic Interference Equipped with an overall copper screen to shield sensitive electronics from EMI.
Harsh Environmental Conditions UV-resistant, halogen-free outer sheath designed to withstand salt spray and humidity.
Safety Requirements Flame retardant and halogen-free materials minimize fire hazards and toxic fume emissions.

Why Choose Feichun Type MVCECH Cables?

  • Durability: Built to last in demanding environments.

  • Safety Assurance: Tested to rigorous international standards (IEC 60092).

  • Enhanced Performance: EMI reduction ensures smooth operation of sensitive equipment.


Powering Marine Vessels: A Guide to Feichun Type MVCECH 3.6/6 (7.2) kV Cable Marine Cables

III. Technical Specifications and Standards Compliance

Engineered for Safety and Performance

Feichun Type MVCECH cables meet stringent international standards for marine applications. Below are the key construction and performance specifications:

Component Material and Features
Conductor Stranded, annealed Class 2 copper for fixed installations (Class 5 available for flexibility on request).
Conductor Screen Semiconductive layer to reduce electrical stress on insulation.
Insulation High-performance HF HEPR Compound, resistant to high temperatures and partial discharges.
Insulation Screen Semiconductive layer for a uniform electrical field.
Core Screen Copper tape screen for shielding and containing the electrical field.
Bedding Halogen-free compound to cushion and protect the cores.
Overall Screen Electrolytic copper braid (90% coverage) minimizes EMI. Tinned copper available for corrosion resistance.
Outer Sheath Flame-retardant, halogen-free, and UV-resistant SHF1 polyolefin compound (SHF2 available on request).

Electrical and Environmental Properties

Property Specification
Rated Voltage 3.6/6 (7.2) kV
Test Voltage 12.5 kV
Operating Temperature Range -40°C to +90°C
Minimum Installation Temperature -15°C
Minimum Bending Radius (Fixed) Single Core: 12xD; Three Core: 9xD

Compliance Standards

  • Construction Standards: IEC 60092/354 for MV marine power cables.

  • Flame Retardancy: IEC 60332/1-2 for single cables, IEC 60332/3-22 Cat A for bunched cables.

  • UV Resistance: ISO 4892-2&3.

  • Halogen-Free: IEC 60754.


IV. Installation Guidelines and Best Practices

Steps for Optimal Performance

Installing medium voltage cables requires meticulous planning and adherence to safety standards. Here are the best practices:

Aspect Best Practices
Safety First Only qualified personnel should handle MV installations. Use appropriate PPE and isolation procedures.
Cable Handling Avoid mechanical damage during transport and installation.
Routing Maintain proper clearances, avoid heat sources, and use suitable cable trays and supports.
Bending Radius Adhere strictly to the minimum bending radius to avoid internal damage.
Termination Use specialized terminations for MV cables, ensuring tight connections and insulation integrity.
Earthing and Bonding Ensure proper earthing of the screen for personnel safety and EMI control.

Powering Marine Vessels: A Guide to Feichun Type MVCECH 3.6/6 (7.2) kV Cable Marine Cables

V. Troubleshooting and Maintenance

Common Issues and Resolutions

Proper maintenance ensures long-term reliability. Here's how to address common problems:

Issue Cause Solution
Insulation Failure Mechanical stress or electrical discharges. Inspect for visible damage and replace the damaged section.
EMI Disturbance Incomplete or poor earthing of the screen. Verify and secure proper earthing connections.
Sheath Damage Abrasions or UV exposure. Conduct regular inspections and use protective coverings.

VI. Technical Information: Tables and Data

Cable Dimensions and Ratings

Conductor Size (mm²) Outer Diameter (mm) Weight (kg/km) Current Rating (A)
25 22 680 120
50 27 1020 160
95 33 1570 215
150 39 2230 280

Core Identification

Core Count Color Coding
Single Core Black
Three Core Brown, Black, Grey


Conclusion: Empowering Marine Vessels with Feichun MV Cables

The Feichun Type MVCECH 3.6/6 (7.2) kV cable stands out as a robust, reliable solution for medium voltage power distribution in marine environments.

With its superior EMI shielding, durable materials, and compliance with international standards, this cable delivers unparalleled performance in even the harshest conditions.

For engineers, installers, and operators looking for safe, efficient, and long-lasting solutions, Feichun MV cables are a trusted choice.

For further inquiries or technical details, contact Feichun Marine Cabling Solutions today!

Powering Marine Vessels: A Guide to Feichun Type MVCECH 3.6/6 (7.2) kV Cable Marine Cables Powering Marine Vessels: A Guide to Feichun Type MVCECH 3.6/6 (7.2) kV Cable Marine Cables Powering Marine Vessels: A Guide to Feichun Type MVCECH 3.6/6 (7.2) kV Cable Marine Cables

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.


Wholesale Powering Marine Vessels: A Guide to Feichun Type MVCECH 3.6/6 (7.2) kV Cable Marine Cables from china suppliers

Powering Marine Vessels: A Guide to Feichun Type MVCECH 3.6/6 (7.2) kV Cable Marine Cables Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Anhui Feichun Special Cable Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)