Sign In | Join Free | My futurenowinc.com
China Anhui Feichun Special Cable Co., Ltd logo
Anhui Feichun Special Cable Co., Ltd
"Feichun Cable: Special wear-resistant flexible cable designed for Reeling & Trailing scenarios!"
Active Member

2 Years

Home > Shipboard & Marine Cables >

Enhanced Safety and Signal Integrity: A Comprehensive Guide to Feichun FM2XCH-FFR Fire-Resistant and Shielded Marine Control and Signal Cables

Anhui Feichun Special Cable Co., Ltd
Contact Now

Enhanced Safety and Signal Integrity: A Comprehensive Guide to Feichun FM2XCH-FFR Fire-Resistant and Shielded Marine Control and Signal Cables

Brand Name : FeiChun™

Model Number : FM2XCH-FFR

Certification : VDE 0250 Part 813

Place of Origin : Hefei Anhui China

MOQ : 200 Meter

Price : 10-50 USD per meter, price varies according to specifications

Payment Terms : T/T, Western Union

Supply Ability : 18,000 meters per week

Delivery Time : 15-30 Work Day

Packaging Details : Cable Reels or Packaging Bags

Voltage Rating : 600V

Water Resistant : Yes

Uv Resistance : Yes

Current Rating : 1000A

High Conductivity Core : Excellent Conductivity

Optimized Bending Radius : Flexible Curvature Design

Maximum Ampacity : 170 Amps

Number Of Conductors : 2 - 37

Shielded : Yes

Chemical Resistance : Chemically Resilient

Stranding : 7 strands

Conductor Integrity : Reliable Conductor Integrity

Uv Stability : UV Stable Structure

Safety Certifications : Certified For Safety

Contact Now

Enhanced Safety and Signal Integrity: A Comprehensive Guide to Feichun FM2XCH-FFR Fire-Resistant and Shielded Marine Control and Signal Cables

Headline: Protecting Critical Control and Signal Circuits: Understanding Feichun FM2XCH-FFR Marine Cables

Enhanced Safety and Signal Integrity: A Comprehensive Guide to Feichun FM2XCH-FFR Fire-Resistant and Shielded Marine Control and Signal Cables

  • Introduce Feichun, a leading provider of advanced marine-grade cabling solutions.

  • Highlight the importance of fire safety and electromagnetic interference (EMI) mitigation for marine control and signal applications.

  • Present the Feichun FM2XCH-FFR, a cable designed specifically for signal transmission in maritime environments, meeting stringent safety and performance standards.


Emphasize the key features:

Twisted pairs for high-frequency signal integrity.

Overall screen to minimize environmental EMI.

Fire resistance for operation in emergency conditions.

  • State the minimum installation temperature: -15°C.

  • Direct readers to the technical section for additional details such as core identification, diameter tolerances, and current ratings.

  • Purpose: Provide a detailed understanding of the cable’s features, applications, installation practices, and challenges to aid engineers and installers.


Enhanced Safety and Signal Integrity: A Comprehensive Guide to Feichun FM2XCH-FFR Fire-Resistant and Shielded Marine Control and Signal Cables

II. Technical Specifications and Standards Compliance

Sub-headline: Engineered for Demanding Marine Environments

1. Construction Standard

  • IEC 60092/376: Governs the design and construction of marine control and signal cables.

2. Materials and Design

Component Material/Design Benefits
Conductor Electrolytic, stranded, annealed copper wire (IEC 60228 Class 2; Class 5 or tinned optional). Low resistance, durability, and corrosion resistance (with tinned option).
Fire Barrier Mica tape Maintains insulation integrity under high temperatures during fire.
Insulation XLPE (Cross-linked polyethylene) High dielectric strength, heat resistance, and moisture protection.
Core Identification White cores with black numbering. Ensures easy and accurate circuit identification.
Inner Covering Separating foil. Prevents interaction between the conductor and the screen.
Screen Electrolytic copper braided screen (Min. 90% coverage; tinned braid optional). Reduces EMI and provides structural integrity.
Outer Sheath Halogen-free, flame-retardant, UV-resistant polyolefin compound (SHF 1). Limits toxic smoke during fire, resists sunlight and UV damage, and ensures environmental safety.
Color Orange or Green. Meets marine identification requirements for specific circuits.

3. Electrical and Environmental Characteristics

Parameter Specification Standard/Significance
Rated Voltage 150 / 250 V Supports low-voltage control and signal systems.
Test Voltage 1.5 kV Ensures dielectric integrity under stress.
Operating Temperature -40°C to +90°C Suitable for harsh marine environments.
Minimum Installation Temperature -15°C Avoids cracking during installation in cold conditions.
Minimum Bending Radius (Fixed) 6xD (6 times cable diameter) Ensures flexibility without damaging internal components.
Flame Retardant IEC 60332/1; IEC 60332/3-22 Cat A Limits flame propagation in single and grouped cables.
Fire Resistance IEC 60331/21; IEC 60331/1-2 Maintains circuit integrity during fire emergencies.
Smoke Emission IEC 61034/1-2 (DIN EN 50268/1-2) Produces minimal smoke for enhanced visibility during fires.
Halogen Content IEC 60754/1-2 Limits toxic gas emissions.
UV Resistance EN 50289-4-17 A&B; ISO 4892-2&3 Prolongs cable life in outdoor environments.

Enhanced Safety and Signal Integrity: A Comprehensive Guide to Feichun FM2XCH-FFR Fire-Resistant and Shielded Marine Control and Signal Cables

III. Installation Guidelines and Best Practices

Sub-headline: Ensuring Reliable Performance and Safety

1. Cable Handling and Routing

Aspect Recommendation
Handling Avoid bending beyond the minimum radius or applying excessive mechanical force.
Routing Keep cables away from heat sources, EMI sources, and power cables to ensure signal integrity.
Supports Use marine-grade cable trays and clamps for secure routing.

2. Termination and Connection

Aspect Recommendation
Screen Termination Use proper grounding techniques to maintain EMI shielding effectiveness.
Core Identification Verify core numbers to ensure accurate circuit termination.
Connector Selection Use fire-resistant and marine-grade connectors.

IV. Common Challenges and Troubleshooting

Sub-headline: Maintaining Reliability

Issue Cause Solution
Damage to Mica Tape Excessive bending or mechanical stress. Handle the cable carefully and adhere to bending radius limits.
Screen Damage Poor termination or mechanical stress. Inspect and repair screen terminations to maintain EMI shielding.
Sheath Damage Abrasion or exposure to sharp objects. Apply protective coatings or replace the damaged section.
Improper Grounding Faulty screen grounding. Ensure all screens are properly terminated and grounded.

V. Conclusion

Sub-headline: Enhanced Safety and Signal Integrity for Critical Marine Systems

  • Reiterate the importance of Feichun FM2XCH-FFR cables in marine environments for fire resistance and EMI shielding.

  • Highlight key features: twisted pairs, advanced screening, and fire-resistant construction.

  • Encourage adherence to installation guidelines for optimal performance.

  • Direct customers to Feichun for more information and technical support.


VI. Appendices (Optional)

  • Glossary of Terms: Definitions of key electrical and marine cable terms.

  • Technical Data Sheet: Comprehensive technical specifications and parameters.

  • Standards References: Excerpts from relevant electrical and marine standards.

Enhanced Safety and Signal Integrity: A Comprehensive Guide to Feichun FM2XCH-FFR Fire-Resistant and Shielded Marine Control and Signal Cables Enhanced Safety and Signal Integrity: A Comprehensive Guide to Feichun FM2XCH-FFR Fire-Resistant and Shielded Marine Control and Signal Cables Enhanced Safety and Signal Integrity: A Comprehensive Guide to Feichun FM2XCH-FFR Fire-Resistant and Shielded Marine Control and Signal Cables

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.


Wholesale Enhanced Safety and Signal Integrity: A Comprehensive Guide to Feichun FM2XCH-FFR Fire-Resistant and Shielded Marine Control and Signal Cables from china suppliers

Enhanced Safety and Signal Integrity: A Comprehensive Guide to Feichun FM2XCH-FFR Fire-Resistant and Shielded Marine Control and Signal Cables Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Anhui Feichun Special Cable Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)